Automatic Infusion Controller

Strengths

Safety

  • Infusing under constant pressure lowers
    the risk of tissue injury by extravasation
  • No chance of rapid infusion
  • Prevent human error with voice feedback

Accuracy

  • Maintains a stable flow rate of infusion from
    beginning to end with an error rate less than 3%
  • Not applying pressure on the tube
    eliminates the chance of IV tube deformation,
    maintaining a consistent flow

Convenience

  • IV set is easy to attach and detach
  • Small and lightweight, easy to move and install
  • Long battery life without power cord
  • User-friendly interface

Features

AccuDrip
(Automatic Infusion controller)

Extravasation, caused by the catheter dislodging blood vessels, occurs at a higher rate than reported in actual clinical practice. Since conventional infusion pumps compress the tube and inject fluid under forced pressure, there is a high risk of tissue damage when extravasation occurs. Therefore, various literature and guidelines recommend that peripheral vesicant drugs such as antineoplastic agents should be administered by gravity drip, not by infusion pump. However, if precise flow rate control is required, there is currently no suitable device other than the conventional infusion pump.

In this respect, AccuDrip's infusion system regulated by flow control valve is the world's only infusion device capable of precise infusion control using gravity drip. It does not infuse fluid over the tissue pressure limit, and the monitoring of drip sensor analyzes the drip interval to turn on an alarm, which decreases the risk of tissue injury by extravasation.



The safety offered by AccuDrip is particularly necessary for
patients at a high risk of extravasation tissue injury, such as

  • Patients receiving anti-cancer therapy (especially adjuvant chemotherapy)
  • Children and newborns
  • Patients receiving at-home care or nursing home patients

Functions

  • Extravasation
    monitor mode

    Alerts when extravasation is suspected for ICU patients

  • Fix Mode

    Fixes valve control with current flow rate when moving patients

  • Sleep mode

    Reduces display brightness for patients' comfortable sleep

  • Real-time
    monitoring

    Alerts when detecting abnormal drip interval

  • User-friendly interface

    Displays real-time flow rate, delivered volume, and remaining time

  • Voice feedback

    Prevents human error by reading entered prescriptions aloud.